Lifts: Planning, designing, and installation guide for architects

Lifts are a key element in several buildings, including homes, apartments, and offices. However, there are so many variations in types and styles of lifts that it can be quite bewildering to figure out the best-suited planning technique. Therefore, it is essential to identify the types of passengers, their traffic flux, the building dimensions, lift location, car arrangement, and other prerequisites during the initial stage of construction to avoid any expensive mistakes.

Every second, someone, somewhere in the world is using them. These vertical movement devices definitely make multi-story buildings more accessible. From a departmental store and shopping mall to metro and subway stations and airports, one can easily find them anywhere.

However, for a professional, efficient lift planning, arrangement, and installation remains extremely important. The key to a successful and smooth operation is proper lift planning, flawless installation, and timely maintenance.

Lift planning is a complex business and there are plenty of opportunities for costly errors. Identify the type of lift, predict the usage & traffic flow, estimate the number and arrangement of lifts required with their dimensions and configurations, and ensure you install the appropriate technology to manage it.

Moreover, as a professional, the objective remains to deliver the best performance to your customers. To achieve this goal, it becomes essential for architects to select the right solutions for the right applications.

This article aims to help all professionals from architects and builders, to manufacturers and consultants plan and design their lift installation projects effectively.

 

Basic terminology of lifts

 

Lifts - Headroom image Lift - Pit depth image

Image Source: Researchgate.net

 

a) Shaft width: It is the clear internal width of the shaft. This width is the lift dimensions that is parallel to the opening and closing direction of the elevator doors.

b) Shaft depth: It is the clear internal depth of the shaft. This depth is the dimension that is perpendicular to the opening and closing direction of the door.

c) Pit depth: It is the vertical distance between the floor level of the lowest-most floor and the floor of the pit.

d) Headroom: It is the vertical distance between the floor levels of the top-most served floor and the underside of the slab at the top of the shaft.

e) Machine room headroom: The headroom inside the machine room is the distance from the floor level on which the motor is placed and the underside of the slab at the roof of the machine room. This ranges from 2000 mm to 4000 mm depending on the size of the motor.

 

Also see: Escalators: A professional’s guide for better planning & installation

 

Factors to be considered while selecting lifts

Lift planning helps in a multitude of ways. With proper planning, you can avoid the lift from looking like an oddball.

The installation and planning of lifts require extensive experience and knowledge. You, along with the entire design team, must go through a few steps in order to plan and design the lift arrangement and installation.

Here is a list of the factors that need to be taken into consideration when planning for lifts:-

 

Peak demand for the building

The type of building largely influences the vertical transportation system required.

The key factors on which the demand depends are population, arrival rate, and pattern.

In some cases, the time of arrival is fixed (offices, etc.) whereas, in others, the time of departure is fixed (theaters, etc.).

Along with the traffic density, traffic flow also plays an important role in determining lift planning. Proper traffic flow management is possible by analyzing the movement of your passengers.

In addition, a uniform arrival or departure pattern can be used to best reflect the need for planning lifts.

Moreover, these are sized on the basis of the percentage of the population arriving in the worst five-minute peak period. However, in some cases, it is more appropriate to use the worst one minute as the basis for design.

This has usually been taken as 12-15% of the population arriving during the worst five-minute peak period. Modern practices show that this figure, in reality, is nearer to 10-12%, due to the prevalence of flexible starting and finishing times.

Therefore, it is important to take into account traffic flow management which means predicting the usage, especially during peak hours. This significantly impacts your decision of how many lifts you require, their type, location, size, arrangement, dimensions, and speed.

Refer to the table below for information on the average waiting time that varies from building to building.

 

Also see: Elevators: How to select the right type based on your requirements?

 

Building type Waiting time (second)
Office building

–          Central town

–          Commercial

 

25-30

30-45

Residential building

–          Luxury

–          Medium

–          Low cost

–          Hostel

 

50-70

60-80

80-120

60-80

Hotel

–          Class A

–          Class B

 

40-60

50-70

 

Capacity

When choosing a specific car, a choice has to be made as to whether the car is selected as a deep car or a wide car as per the lift dimensions.

Generally, wide cars are preferable to deep cars as they provide better passenger transfer and achieve higher car capacities. Deep cars, on the other hand, are suitable for wheelchair users. Similarly, open cars serve the dual purpose of carrying passengers as well as for the movement of goods.

Next, it is recommended to decide the ideal dimensions for the lift shaft and the machine room, pit depth, and headroom.

For this purpose, once the number of lift cars, their dimensions, arrangement, and speed are decided, you may use either use a specific manufacturer’s data sheets or use generic dimensions as provided by standards.

Before choosing the type, you need to calculate the expected building capacity. This will give you a clear idea of the lift car capacity and ideal waiting time for your building.

For instance, if yours is a high-traffic building that needs fast service, you need one lift per 150-200 passengers.

However, if you want moderate or economy-oriented service, a lift car per 250-300 passengers will offer better outputs.

On the contrary, a hotel needs one lift car per 90-120 rooms.

Here is a tabular representation for better understanding:-

Function        Capacity (lbs.) Min. speed (ft. /min.) Building height (ft.)
Office building:-

Small

 

Medium

 

Large

 

2500

 

3000

 

3500

 

350-400

500-600

700

800

1000

 

0-125

126-225

226-275

276-375

>375

Hotel 2500

3500

Same as above

 

Hospital 3000

 

3500

 

4000

150

200

250-300

350-400

500-600

700

0-60

61-100

101-125

126-175

176-250

>250

Residential 2000

 

2500

 

100

200

250-300

350-400

0-75

76-125

126-200

>200

Commercial 3500

4000

 

5000

200

250-300

350-400

500

0-100

101-150

151-200

>200

 

Quantity of Service

The quantity of service is best reflected by the number of passengers moved to their destination. This is measured considering the number of passengers handled during five minutes each of the peak periods of the day.

This is also known as the handling capacity.

Handling capacity is calculated by the following formula:-

H= (300 x Q x 100) / T x P

Where,

H= Handling capacity as the percentage of peak population handled during 5 minutes,

Q= Average number of passengers carried in a car (depends on the dimensions of the lift car),

T= Waiting interval, and

P= Total population to be handled

 

The waiting interval is calculated by the following formula:-

T= RTT / N

Where,

T= Waiting interval

N= Number of lifts, and

RTT= Round Trip Time (average time taken by a fully-loaded lift to go from the ground floor, discharge the passenger on various upper floors, and come back to the ground floor)

Note: As the number of stops reduces, the round trip time reduces. This results in reducing the waiting interval and also increasing the handling capacity.

 

Quality of service

Unlike quantity, the quality of service is measured in the interval between the arrivals. It reflects the passenger waiting time for various floors and is also called waiting interval.

Here is a table representing the quality of service or waiting interval:-

Time taken Quality of service
20-25 seconds Excellent
30-35 seconds Good
35-40 seconds Fair
40-45 seconds Poor
Over 45 seconds Unsatisfactory

 

Speed

The speed is dependent upon the quality and quantity of service. Therefore, there is no standard formula to measure it.

Additionally, the motor needs to be sized based on capacity and speed.

 

Here is a table enumerating the recommended speeds of various types:-

Number of floors Recommended speed
Office building 

–          4-5 floors

–          6-12 floors

–          Over 12 floors

 

1 MPS

1.5 MPS

Over 1.5 MPS

Residential building 

–          4-8 floors

–          8-12 floors

–          Over 12 floors

 

1 MPS

1.5 MPS

Over 1.5 MPS

Hospital 

–          Up to 4 floors

–          5-8 floors

–          Over 8 floors

 

0.5 MPS

0.75 MPS

Ads

1 MPS

Goods 

–          Up to 6 floors

–          Over 6 floors

 

0.5 MPS

0.75 MPS

 

User behaviour

The people, who use the lift, are relevant in their choice. The features can largely be governed by it. Therefore, it is worth discovering the user pattern. However, you need to be very careful of the specifications that you need.

Therefore, ask the following questions before choosing your type:-

  • What kind of people will use the lift?
  • Do they need assistance or can they use it independently?
  • What kind of luggage or goods is generally expected?
  • Do I require additional movement devices such as escalators or walkways as well?

In addition, an inclined walkway or escalator has a set of pros and cons. Typically, these are not considered suitable for wheelchair users due to the incline.

 

Building space vs lift space

This aspect becomes even more important when you want to install a lift in an existing building.

A normal passenger lift needs a pit depth of at least 1100 mm and a headroom of 3400 mm.  However, if you do have a pit space, you can fit a ramp instead with some extra space on the lowest floor of your building.

Moreover, if you already have an existing shaft, it remains best to ask the manufacturing company to conduct a site survey and recommend the best product.

 

Drive system

A decision has then to be made regarding the type of drive. Following are a few options available:-

  • Hydraulic
  • Traction
  • Machine room-less (MRL)

In certain cases, rack & pinion lifts can also be used.

 

Safety

Last but not least, it is of utmost importance to ensure that the machine complies with fire and safety standards.

If your building is a certain size, the law generally requires that you install a specifically designed firefighter’s lift. Also, depending on the height above ground or depth below ground, a firefighting elevator might be needed.

In these cases, the number of elevators depends on the floor area of the premises. A fire-fighting elevator needs to be in accordance with the latest standards.

In order to comply with fire regulations, it needs fire-rated doors, a backup power supply, a larger car, set speeds, an internal communication system, and built-in water protection for fire fighting run-off.

 

Budget

At this stage, when all other boxes have been checked, it is well-advised to get a quotation from a number of suppliers. This is especially important if the lift has any special features like low noise, high-level finishing, etc., or is a completely non-standardized product.

 

Energy consumption

In certain cases, the client might be interested in getting an estimate of the energy consumption of the new installation. While in other projects, the reduction in the energy consumed can be used to justify the refurbishment of an installation.

 

Types of lifts

Based on the previous questions, figure out your basic requirements and then choose the best type for your building:-

 

Passenger lift

A lift designed for carrying passengers. It can go up to 40 m and even more.

 

Goods lift

A lift designed primarily for the movement of goods rather than passengers. However, it may carry an attendant as well.

 

Service lift

A lift with a car exclusively used for carrying materials. Typically, these do not carry any person. Moreover, it has a total inside height of 1.25 m and a maximum capacity of 250 kg.

 

Hospital lift

A lift is installed in a hospital or clinic. Such lifts are designed to accommodate one bed or stretcher along with its depth, with sufficient space to carry attendants and a lift operator.

 

Platform lift

Generally used in low-rise buildings by wheelchair users. The platform lift goes up to 12 m.

 

Glass lift

Mostly used in hotels and places that need aesthetic lifts. The glass lift is a stylish alternative to a passenger lift.

 

Trolley lift

The trolley lift carries larger goods on roll cages and trolleys.

 

Stair lift

Mostly used in homes for individuals in wheelchairs.

 

Firefighting lift

The firefighting lift offers additional protection against fire. A firefighting lift is needed in a building with more than 18 meters above or 10 meters below the fire service vehicle access level.

 

Positioning the lift

When arranging the lifts, there is a need to consider their position. A thorough analysis should be done to assess the most suitable position for lift(s).

Very high-rise buildings require either multiple lifts or lifts with a high-load-bearing capacity. Additionally, the right positing of the lift also plays a major role in determining the smooth functioning of the lift system.

There are three main positions of a lift in a building:-

 

Inside the building

  • In the stairwell, if it is large enough to accommodate a lift.
  • By creating a new interior shaft in a position independent of the stairs in spacious areas with small stairways.

 

Outside the building

  • On the outside wall with access to the building landing through an interior or exterior public area.
  • Adjacent to the doorway, rebuilding the entrance through an existing doorway.

 

Next to the staircase

As a professional, it remains your job to identify the best arrangement for lift in your building.

Initially, the placement of a lift between the staircase or adjacent to it was a preferred choice. However, it posed a threat to safety in case of a fire outbreak. Therefore, today, lifts are placed near the staircase and not attached to it.

Another suitable choice remains the floor deck. However, the architect or designer must offer adequate floor deck space in the designing stage itself.

Additionally, installing a lift near the windows makes it easier to cut and carve the lift door openings.

Choose an easily accessible, clear, and open space with no walkway obstructions for lift positioning.

If a lift installation inside the building remains an impossible option due to some reason, you may install outdoor lifts. However, ensure that the building standards remain unchallenged. Also, do not install a lift over a bore (water table) or close to the property boundary.

 

Lift arrangement

The lift arrangement should be such that it minimizes the walking distance from all entrances to the building. For maximum efficiency, they should be installed near the centre of the building.

In order to ensure minimum interference, the maximum travel distance between users and the lift should be 150-200 ft.

The system layout and planning are dependent on the number of lift cars used.

 

2 car lift arrangement

 

Image Source: Slideshare document by KetheesWaran

 

3 car lift arrangement

 

Image Source: Slideshare document by KetheesWaran

 

4 car lift arrangement

 

Image Source: Slideshare document by KetheesWaran

 

6 car lift arrangement

 

Image Source: Slideshare document by KetheesWaran

 

8 car lift arrangement

Image Source: Slideshare document by KetheesWaran

 

Moreover, the following points are important when it comes to the arrangement of lifts:-

  • When more than one lift is installed in a group, they shall be arranged side by side or in two rows facing each other. Separation in the group shall be avoided.
  • The lift lobby in front shall be wide enough to allow sufficient space for waiting passengers and proper vision of hall buttons and hall lanterns. As part of the planning process, more space shall be allowed in front of the lifts on the main floor than on the upper floors.
  • It is preferable that the lift lobby is not used as a thoroughfare, but when absolutely needed the lobby shall be wider enough to take into account the space for people who are moving.

 

Basis of lift arrangement

 

Space requirement

It is important to consider the space requirements while planning and selecting lifts. It is necessary to clearly specify the lift dimensions. This can be done by determining the following parameters:-

a) Shaft width

b) Shaft depth

c) Pit depth

d) Headroom

e) Machine room headroom

 

Safe access to the pit

In addition to this, to achieve safe access to the pit, the following is required depending on the pit depth:-

a) Pit depth < 1 m: In this case, no special arrangements are needed.

b) Pit depth from 1- 2.5 m: A permanent fixed ladder is required in the shaft that is accessible from the lowest landing.

c) Pit depth > 2.5 m: In this case, a walk-in pit arrangement must be provided. The lift door dimensions have to be at least 350 mm wide by 1800 mm high.

d) The facility of good lighting within the pit must be present.

e) A stop switch must be provided inside the shaft that is accessible from the lowest landing. This is to provide safe access for the maintenance staff accessing the pit.

f) Where a number of elevators are located adjacent to each other in the same shaft, a divider beam must be installed in the shaft with an allowance of 150 mm to 200 mm.

 

Schedule preparation

Next, a schedule is to be prepared to provide all the details of every elevator. It should contain the following points:-

a) An identifier

b) Lift group

c) The number of lifts in each group

d) Usage (passenger, office, hospital, goods, etc.)

e) Floors served

f) Capacity in kg and persons

g) Number of entrances

h) Speed

i) Width of car

j) Depth of car

k) The internal height of the car (usually 2300 mm which can go up to 2700 mm in certain cases)

l) Shaft width

m) Shaft depth

n) Door width

o) Door height (typically 2100 mm)

p) Lift door arrangement which is either a two-panel centre opening (2PCO) or two-panel side opening (2PSO)

q) Open through, having a front door and a rear door

r) Provision of ventilation

s) Shaft headroom

t) Pit depth

u) Safety gear on the counterweight if there are any accessible areas under the pit

v) Type of drive which could be electrical traction or hydraulic

w) Location of drive which could be above the shaft, below the pit, or to the side of the shaft

x) Headroom of the machine room that can range from 2000 mm to 4000 mm depending on the size of the drive motor

y) Size and position of any footing or grillage

 

Dimensions of lifts on the basis of lift arrangement

Lifts or elevators, should be arranged around a series of design factors that include: the type of occupancy, dimensions, speed and quantity of traffic, total vertical distance to be traveled, and the desired time and speed of travel.

In addition to that, there are a few more important factors to be considered, namely: safety, quality, aesthetics, capacity during peak times, and the type of building in which the elevator is to be installed.

A common residential lift is usually 3’ wide by 4’ deep or 0.91 x 1.22 m in dimensions. The door width is usually 36 inches or 0.91 m.

On the other hand, for office buildings, lifts are typically 6’ wide by 5’ deep or 1.83 x 1.53 m in dimensions. The door width is typically 4’ wide or 1.22 m.

 

Most common and preferred lift arrangements & layouts

 

2 car lifts

2 car lift layout and dimensions
2 car lift layout and dimensions

Image Source: Dimensions.com

 

  • Cars/lifts: 2
  • Width: 18’1” or 5.5 m
  • Depth: 18’6” or 5.6 m
  • Area: 333 sq. ft. or 31 sq. m.
  • Elevator depth: 7’11” or 2.4 m
  • Waiting depth: 10’ or 3 m or 1.5x car depth

These lifts have a low-capacity layout. Widely used in buildings with limited load, two lift elevator banks are ideal for offices with floor areas around 90,000 sq. ft. or 8,361 sq. m., hotels with 150 rooms, and housing projects with 180 units.

Two lift elevator banks have typical widths of 18’ or 5.5 m and depths of 18’6” or 5.6 m which is a combination of a single row of lifts and an adjacent waiting area with a clearance width (lobby) of 10’/3 m, or 1.5 x car depths

Therefore, these have an overall area of around 333 sq. ft. or 31 sq. m.

 

3 car lifts

3 car lift layout and dimensions
3 car lift layout and dimensions

Image Source: Dimensions.com

 

  • Cars/lifts: 3
  • Width: 26’9” or 8.2 m
  • Depth: 18’6” or 5.6 m
  • Area: 494 sq. ft. or 46 sq. m.
  • Elevator depth: 7’11” or 2.4 m
  • Waiting depth: 10’ or 3 m or 1.5x car depth

These have a low to medium-capacity layout. Most commonly used in buildings with low to medium loads, three lift elevator banks are ideal for offices with floor areas around 135,000 sq. ft. or 12,542 sq. m., hotels with 225 rooms, and housing projects with 270 units.

These have typical widths of 27’ or 8.2 m and depths of 18’6” or 5.6 m which is a combination of a single row of lifts and an adjacent waiting area with a clearance width (lobby) of 10’ or 3 m or 1.5 x car depths in lift dimensions.

Therefore, these have an overall area of around 494 sq. ft. or 46 sq. m.

 

4 car lifts

4 car lift layout and dimensions
4 car lift layout and dimensions

Image Source: Dimensions.com

 

  • Cars/lifts: 4
  • Width: 35’8” or 10.9 m
  • Depth: 18’6” or 5.6 m
  • Area: 658 sq. ft. or 61 sq. m.
  • Elevator depth: 7’11” or 2.4 m
  • Waiting depth: 10’ or 3 m or 1.5x car depth

These have a medium-capacity layout. Commonly used in buildings with medium average load, four lift elevator banks are ideal for offices with floor areas around 180,000 sq. ft. or 16,723 sq. m., hotels with 300 rooms, and housing projects with 360 units.

These have typical widths of 36’ or 10.9 m and depths of 18’6” or 5.6 m which is a combination of a row of lifts and an adjacent waiting area with a clearance width (lobby) of 10’ or 3 m or 1.5 x car depths.

Therefore, these have an overall area of around 658 sq. ft. or 61 sq. m.

 

6 car lifts

6 car lift layout and dimensions
6 car lift layout and dimensions

Image Source: Dimensions.com

 

  • Cars/lifts: 6
  • Width: 26’9” or 8.2 m
  • Depth: 26’4” or 8 m
  • Area: 704 ft2 or 65 m2
  • Elevator depth: 7’11” or 2.4 m
  • Waiting depth: 10’6” or 3.2 m or 1.75x car depth

These have a medium to high-capacity layout. Commonly used in buildings with a large load, six lift elevator banks are ideal for offices with floor areas around 270,000 sq. ft. or 25,084 sq. m., hotels with 450 rooms, and housing projects with 540 units.

These have typical widths of 27’ or 8.2 m and depths of 27’ or 8.2 m which is a combination of two rows of lifts around a central waiting area with a clearance width (lobby) of 10’6” or 3.2 m or 1.75x car depths.

Therefore, these have an overall area of around 704 sq. ft. or 65 sq. m.

 

8 car lifts

8 car lift layout and dimensions
8 car lift layout and dimensions

Image Source: Dimensions.com

 

  • Cars/lifts: 8
  • Width: 35’8” or 10.9 m
  • Depth: 27’10” or 8.5 m
  • Area: 992 sq. ft. or 92 sq. m.
  • Elevator depth: 7’11” or 2.4 m
  • Waiting depth: 12’ or 3.7 m or 2x car depth

These have a high-capacity layout. Commonly used in buildings with a large load, eight lift elevator banks are ideal for offices with floor areas around 360,000 sq. ft. or 33,445 sq. m., hotels with 600 rooms, and housing projects with 720 units.

These have typical widths of 36’ or 10.9 m and depths of 28’ or 8.5 m which is a combination of two rows of lifts around a central waiting area with a clearance width (lobby) of 12’ or 3.7 m or 2x car depths.

Therefore, these have an overall area of around 992 sq. ft. or 92 sq. m.

 

Lifts rules and regulations in India

Most Indian states lack a defined Lift Act. Therefore, ambiguity persists when it comes to the legal aspects of the installation. However, some common doubts have been cleared in this article so as to assist the professionals.

a) Buildings taller than 15m need 8 passenger fire lift with a maximum speed enough to reach the topmost floor in 60 seconds and automatic doors.

b) Ten Indian States- Delhi, Maharashtra, Karnataka, Gujarat, Tamil Nadu, Assam, Himachal Pradesh, West Bengal, Haryana, and Kerala offer lift licenses.

c) Permission is required for the election of a lift in a building.

d) IS-complaint elevators must be used for the safety of equipment as well as passengers.

Indian Standards for different types of elevators:-

  • Home lift: IS 14665 and IS 15259
  • Machine room-less lift: IS 15785
  • Hydraulic lift: IS 14671

e) A home lift’s load capacity must range from 204 kg to 272 kg only. The lift car speed must not exceed 0.2 MPS.

 

Also see: Top 10 architects in Mumbai | Best architecture firms in Mumbai

 

Conclusion

Lift planning remains a tricky business wherein a lax approach results in costly errors.

This device for a commercial building and home comes with separate requirements, limitations, and challenges. Therefore, you need to understand the nuances of your space first.

A lift for home comes in various lift sizes, types, and designs. Working in close coordination with the clients, consultants, architects, and the manufacturing company offers the best results.

In construction, these are the backbone of a building, providing support for the layout, as well as access and transportation.

Although the basic properties remain quite similar across the industry, these serve a broad range of applications. Services, hospitals, and goods lifts are mainly delineated by their dimensions and capacity. On the other hand, commercial and residential elevators offer the liberty to design and arrange them in multiple layouts.

No matter which location you choose, the process of planning, installation, and arrangement will ultimately prove to be beneficial regardless of location.

Moreover, to ensure that there is no interference between passengers entering and exiting the car, it is important to focus on the arrangement. It should be planned carefully to obtain maximum efficiency.

Systems with a different number of lift cars have different dimensions as well. Hence, it is important to ensure optimal usage and short waiting time.

Additionally, no one likes to land into legal trouble. Hence, give serious attention to the regulations and guidelines related to the installation of the place, city, and state you are working in.

Therefore, thinking beyond the obvious is the key!

With this detailed understanding of the elements focusing on lift designing & installation in different commercial and residential establishments, it is expected that the professionals will find the required assistance in planning, designing, and installing them meticulously.

 

Sources

  • Slideshare document by KetheesWaran
  • Slideshare document by MitaliGondaliya
  • archi-monarch.com
  • dimensions.com
  • designingbuildings.co.uk
  • researchgate.net
  • architizer.com

 

If you want to buy top-quality lifts from the best brands, click on the link given below to check your options and submit your inquiries:

 

Elevators & Lifts

 

For more details, contact below:

WhatsApp Number: +91-9967632127 (Only message; no calls)

Email: support@buildingandinteriors.com

 

Subscribe Our Newsletter

whatsapp
arrow Scroll to Top

Subscribe to our Newsletter